Europe’s most advanced data centre – is the latest addition to Telehouse’s iconic London Docklands Campus. Opened in summer 2016, Telehouse North Two data centre clients can be part of Europe’s leading connectivity hub with over 530 carriers, ISP’s and ASP’s flowing into the Docklands campus. Clients have access to an unparalleled 73,400 sqm of space, with high density power solutions available.

Telehouse North Two will be setting new standards in data centre efficiencies by incorporating the world’s first multi storey adiabatic cooling system – delivering an industry leading PUE of 1.16.

As the primary home of the London Internet Exchange (LINX), the Docklands campus has around 900 private and public peering ports into LINX, making Telehouse Europe’s leading connectivity hub. With ultra-low latency routes to Europe, America, Africa and Asia, the Docklands campus is the ideal location for cloud and content service provision.

Step into North Two – Take a virtual tour of Europe’s most advanced data centre

Europe's most advanced data centre

Future proof power

Telehouse is the only UK data centre campus with its own privately owned 132KV Grid Substation providing clients with an industry leading power density.

Unrivalled connectivity

Europe’s leading connectivity hub with over 530 cloud and connectivity partners flowing into the Docklands campus, making it a unique place to create business opportunities.

World leading cooling

With the world’s first multi-storey indirect adiabatic cooling system, and designed to BREEAM Excellent standard, clients benefit from housing their ICT infrastructures in an efficient and highly resilient data centre.

Colocation

Telehouse North Two can provide Shared Facilities Management (SFM) and Dedicated Facilities Management (DFM). Retail and wholesale options are available.

Data centre specifications

  • The only UK carrier-neutral data centre that owns an on-campus 132kV grid substation providing clients with an industry leading power density
  • 4.5kW average power per rack
  • Dual redundant and diverse incoming power feeds
  • 8 x Generators with N +1 redundancy with a total capacity of 18.5MW
  • Redundant A & B power feeds to customer equipment from 2(N+1) configuration UPS
  • Awarded BREEAM Excellent standard
  • The world’s first multi storey adiabatic cooling system addresses the restrictions driven by load fluctuations.
  • Delivering an industry leading PUE of 1.16 in an N+2 configuration into hot aisle containment
  • ASHRAE room design temperature: 25 +2/-7 °C
  • Carrier neutral facility offering customers freedom of choice
  • As the primary home of the London Internet Exchange (LINX), the Docklands campus has around 900 private and public peering ports into LINX, making Telehouse Europe’s leading connectivity hub
  • Access to over 530 carriers on campus
  • Ultra-low latency routes to Europe, America, Russia, Africa and Asia
  • Diverse entry points into the building
  • With the Interlink Service clients can connect to any carrier from any Telehouse data centre
  • Very early smoke detection alarms (VESDA) installed throughout the facility
  • Fully addressable two stage fire detection system that monitors both under-floor and the room itself
  • Detectors with 50% mix of optical and ionisation are split across 2 separate zonal-loops, to meet BS 5839, 6266, 5445 and 5588
  • Dry sprinkler fire detection system to meet BS 5306, 3115 and with LFEPA approval
  • Ceilings, walls, floors and doors comply with RF90 (fire resistance 90 mins) in DC areas, telecom and plant areas
  • Perimeter protected by alarmed fences and PIR detection
  • Gated entrances manned 24/7 combined with a security management system to ensure no unauthorised access to the site
  • Over 400 movement activated CCTV coverage for the Perimeter, Entrances and Loading Docks, Common areas reception and corridors and of course our state of the art suites
  • Single point of entry to our main facilities controlled by time limited access cards combined with card Independent client card identification access system and integrated digital video camera surveillance
  • Proximity card access is provided from the main data centre building and is issued to provide access only to authorised facilities management suites
  • Strict security processes are in place to ensure delivery and loading of goods are secure
  • Doors fitted with alarms that immediately report back to a manned security suite when unauthorised access is attempted or doors are forced or held open
  • A highly trained Security presence 24/7 to ensure that you and your nominated staff gain authorised access to the facility whenever you require, day or night
  • Test and build rooms available on site
  • Conveniently located close to the city of London
  • Designed to BREEAM Excellent standard
  • ISO 9001 Quality Management
  • ISO 27001 Information Security
  • ISO 14001 Environment Management
  • ISO 50001 Energy Management
  • OHSAS 18001 Occupational Health & Safety
  • ISO 22301 Business Continuity